UKAS Lab 0625 | ISO/IEC 17025:2017 | Southampton
UKAS calibration for Southampton
An audit date does not move because a calibration supplier is slow. Labcal calibrates gas and air flow, liquid flow, pressure, temperature, humidity and air velocity instruments at its UKAS-accredited laboratory in Lymington, around 40 minutes from Southampton, with certificates back in 7 working days on average.
7
Working day average turnaround
3-day fast-track available
6
Parameters, one lab
Gas flow, liquid flow, pressure, temp, humidity, velocity
0625
UKAS Lab Number
ISO/IEC 17025:2017 accredited
1
Working day response
We respond to all enquiries within one working day
Southampton logistics
The shortest journey is the one your instrument is not making
Large calibration networks often route instruments through regional hubs. For a Southampton site, a UKAS laboratory covering all six parameters is a short local journey away.
Labcal is based on Ampress Park in Lymington, in the same SO postcode area as Southampton. An instrument sent from the Western Docks, Chilworth or Eastleigh makes a short regional journey rather than a cross-country transfer, so less of your turnaround is spent in transit.
That matters most when you are running without spares. A shorter out-of-service window means fewer duplicate instruments to buy, hire or borrow while the originals are away, and less pressure on the people covering for them.
Ampress Park, Lymington SO41 8JU
7 working days on average, 3-day fast-track
Like-for-like, within one working day
For regular or high-volume customers
Southampton’s industries
What Southampton’s industries need calibrated, and why
Southampton’s economy is built around the port, energy and process sites on Southampton Water, research and life sciences, and healthcare. Each one leans on a different mix of measurements.
Port, terminal and marine operations
Wind speed limits govern when cranes and lifting equipment can work, so the anemometers that enforce them need calibration you can defend. Hydraulic and pneumatic pressure gauges on handling equipment sit on the same maintenance schedule.
Energy and process sites on Southampton Water
Process plants depend on pressure gauges, transmitters, flow meters and temperature probes whose readings feed safety and operating decisions. Bringing them under one UKAS schedule gives every inspection the same certificate format.
Research and life sciences
Laboratories around Southampton Science Park and the city’s research base rely on temperature probes, data loggers, humidity sensors and mass flow controllers. Labcal supports customers operating under GMP and ISO 13485.
Healthcare, cleanrooms and building services
Portable anemometers used to commission fume cupboards and cleanrooms are commonly calibrated every year, along with the temperature and humidity instruments that monitor controlled environments.
Testing and calibration laboratories
Hampshire laboratories with their own UKAS scope often need a partner for the parameters they do not hold. Labcal covers all six parameters under one schedule.
Manufacturing and engineering
ISO 9001 sites around Southampton, Totton and Eastleigh need traceable evidence for every instrument that affects product quality. One supplier for all of them means one approved supplier record and one audit trail.
Turnaround at a glance
From your Southampton site to a UKAS certificate
Short transit at both ends means more of the turnaround is spent on calibration, not in a van.
Courier from your Southampton site, or collection for regular customers.
Instruments are booked in at Ampress Park, Lymington.
Average from arrival, with a 3-day fast-track by arrangement.
Results and expanded uncertainty (k=2) at every calibrated point.
Calibration for Southampton
How calibration works for Southampton businesses
Whether your instruments sit at the port, in a lab on Southampton Science Park or on a production line in Eastleigh or Totton, the process is the same: pack, send, and receive certificates you can hand straight to an auditor.
- Tell us what needs calibrating Send instrument types, quantities and the parameters involved through the form below. We respond to all enquiries within one working day with a price and turnaround.
- Pack and send from Southampton Use your own courier or ask Labcal to arrange collection. Lymington is roughly 40 minutes by road from Southampton, so next-day services cover the journey comfortably. Collection is available for high-volume or regular customers.
- Calibration at UKAS Lab 0625 Instruments are calibrated in our Lymington laboratory against reference standards with a documented traceability chain. Average turnaround is 7 working days from arrival, with a 3-day fast-track by arrangement.
- Certificates back to Southampton Every instrument returns with a UKAS certificate showing results and expanded uncertainty (k=2). Keep them for your ISO 9001, ISO 13485, GMP or client audits.
Who in Southampton uses Labcal
Quality and compliance managers who need UKAS evidence for an upcoming audit and one supplier for every parameter.
Procurement teams consolidating calibration spend across several sites in Hampshire and the Solent.
Engineers and metrologists with an instrument that has failed a site check and needs a fast, certified recalibration.
Testing and calibration labs in Hampshire that subcontract parameters outside their own UKAS scope.
Why quality teams choose Labcal
One UKAS schedule covering every parameter you measure
Three reasons quality managers, metrologists and procurement teams in Hampshire and the Solent consolidate their calibration with Labcal.
Six parameters, one accredited supplier
Gas and air flow, liquid flow, pressure, temperature, humidity and air velocity are all held on one UKAS schedule under Lab 0625. Consolidate your programme with a single accredited supplier instead of splitting it across several labs and certificate formats.
Audit-ready, traceable certificates
Every certificate carries documented uncertainty of measurement and a traceability chain back to national standards. Labcal supports customers operating under ISO 9001, GMP and similar quality frameworks that require UKAS-accredited evidence.
Fast, predictable turnaround
Average turnaround is 7 working days from receipt at our Lymington laboratory, with a 3-day fast-track available by arrangement. We can arrange courier collection from Southampton for high-volume or regular customers.
Accredited scope
What Labcal calibrates, and the ranges we are accredited for
Every range below is taken from Labcal’s UKAS schedule of accreditation (Lab 0625, issue 055, August 2026). If your instrument falls inside these ranges, it can be calibrated with a UKAS certificate.
Temperature
UKAS accreditedDigital thermometers, resistance thermometers (PRTs), thermocouples, temperature probes, data loggers, and electrical calibration of temperature indicators and simulators.
| Method | Accredited range | Best expanded uncertainty (k=2) |
|---|---|---|
| Resistance thermometers in block or fluid baths | -30 °C to +140 °C | 0.10 °C |
| Base metal thermocouples in baths | -30 °C to +140 °C | 0.25 °C |
| Temperature probes in air (environmental chamber) | -5 °C to 60 °C | 0.15 °C |
| Thermocouple indicator simulation, types T, N, K, J, E | -200 °C to +1372 °C (upper limit depends on type) | 0.50 °C |
| Thermocouple indicator simulation, types S and R | 0 °C to 1760 °C | 0.90 °C |
| PRT indicator simulation (Pt50 to Pt1000) | -200 °C to 850 °C | 0.16 °C to 0.36 °C |
Gas & Air Flow
UKAS accreditedMass flow meters and controllers, variable area flow meters, gas meters and sonic nozzles. Calibration medium is air; other gases can be used up to 300 l/min. Flow and pressure devices with an electrical output can be calibrated.
| Method | Accredited range | Best expanded uncertainty (k=2) |
|---|---|---|
| Prover and reference meter methods | 0.024 ml/min to 0.5 ml/min | Q[1.4 %, 0.0016 ml/min] |
| Prover and reference meter methods | 5 ml/min to 10 l/min | 0.15 % |
| Prover and reference meter methods | 0.5 l/min to 2000 l/min | 0.17 % |
| Prover and reference meter methods | 500 l/min to 12,983 l/min | 0.30 % |
Air Velocity
UKAS accreditedVane anemometers, thermal (hot wire) anemometers and pitot tubes, calibrated in Labcal’s wind tunnels. Anemometers up to 125 mm diameter in the main tunnel; larger instruments in the second facility.
| Instrument | Accredited range | Best expanded uncertainty (k=2) |
|---|---|---|
| Thermal anemometers | 0.1 m/s to 38 m/s | Q[0.18 %, 0.030 m/s] |
| Vane anemometers | 0.3 m/s to 38 m/s | Q[0.22 %, 0.040 m/s] |
| Pitot tubes | 2 m/s to 38 m/s | Q[0.18 %, 0.030 m/s] |
| Large anemometers and pitot tubes (second facility) | 5 m/s to 50 m/s | Q[1.7 %, 0.16 m/s] to Q[1.7 %, 0.88 m/s] |
Pressure
UKAS accreditedPressure gauges, digital pressure indicators, transducers and transmitters, manometers and low differential pressure instruments. Methods consistent with EURAMET CG-17.
| Medium | Accredited range | Best expanded uncertainty (k=2) |
|---|---|---|
| Gas, gauge (vacuum) | -100 kPa to 0 Pa | Q[0.010 %, 41 Pa] |
| Gas, gauge (low differential) | 0 Pa to 3 kPa | Q[0.016 %, 0.070 Pa] |
| Gas, gauge | 3 kPa to 9 kPa | Q[0.016 %, 0.31 Pa] |
| Gas, gauge | 9 kPa to 40 kPa | Q[0.010 %, 3.4 Pa] |
| Gas, gauge | 40 kPa to 500 kPa | Q[0.010 %, 41 Pa] |
| Gas, gauge | 500 kPa to 8.2 MPa | Q[0.010 %, 710 Pa] |
| Gas, absolute (barometric) | 80 kPa to 115 kPa | 0.010 % |
| Hydraulic, gauge and absolute | 500 kPa to 140 MPa | 0.010 % to 0.014 % |
Liquid Flow
UKAS accreditedTurbine, Coriolis, electromagnetic and positive displacement flow meters, calibrated gravimetrically with water for mass, volume, flow rate and quantity passed.
| Method | Accredited range | Best expanded uncertainty (k=2) |
|---|---|---|
| Gravimetric, water | 0.5 ml/min to 500 ml/min | 0.17 % |
| Gravimetric, water | 500 ml/min to 2 l/min | 0.20 % |
| Gravimetric, water | 2 l/min to 450 l/min | 0.14 % |
Humidity
UKAS accreditedRelative humidity probes, hygrometers, transmitters and combined temperature and humidity instruments, calibrated in an environmental chamber against reference meters.
| Quantity | Accredited range | Best expanded uncertainty (k=2) |
|---|---|---|
| Relative humidity at 15 °C to 40 °C | 10 %rh to 90 %rh | 1.5 %rh |
| Relative humidity at 10 °C to 15 °C | 15 %rh to 90 %rh | 1.5 %rh |
| Temperature probe built into humidity meter | -5 °C to 40 °C | 0.15 °C |
| Dew point | -15 °C to 40 °C | 0.18 °C |
Uncertainties are the best expanded uncertainties (k=2) on the schedule and depend on the instrument under test. Q[a, b] is the root sum square of a percentage of reading and a fixed value, as written on the UKAS schedule. Where an instrument falls outside an accredited range Labcal can usually offer a traceable (non-UKAS) calibration; say so in your enquiry and we will confirm.
Calibration Services
What can we calibrate for you?
All six parameters are UKAS-accredited under one roof. Choose a parameter to see the full scope, instrument types and how to prepare your equipment for dispatch from Southampton.

- Six parameters on one schedule
- Expanded uncertainty (k=2) on every certificate
- Independent of any instrument manufacturer
Switching labs in Southampton?
Send us your current certificate for a like-for-like quote.
Around half of the quality managers who enquire with us are leaving another calibration provider. We will match your existing scope, parameters and tolerances, then come back with a price and turnaround within one working day. No switching cost, no rework.
Common Questions
What Southampton calibration buyers ask most
Straight answers to the questions quality managers and procurement teams ask before choosing a UKAS calibration laboratory.
Is there a UKAS calibration laboratory near Southampton?
Yes. Labcal is a UKAS-accredited calibration laboratory (Lab 0625, ISO/IEC 17025:2017) at Unit 265, Ampress Park, Lymington, Hampshire SO41 8JU, around 40 minutes from Southampton and in the same SO postcode area. Labcal calibrates gas and air flow, liquid flow, pressure, temperature, humidity and air velocity instruments under one schedule of accreditation.
How long does calibration take for a Southampton business?
Average turnaround is 7 working days from the day instruments arrive at the Lymington laboratory. A 3-day fast-track is available by arrangement for instruments needed back urgently, for example ahead of an audit. Because Southampton is close to the lab, courier transit adds very little to the overall time.
Does Labcal calibrate on site in Southampton?
No. All Labcal calibration takes place in the Lymington laboratory, where reference standards, wind tunnels and the environmental chamber are controlled to the conditions on the UKAS schedule. For regular or high-volume Southampton customers, Labcal can arrange collection from site.
How do I get a quote for calibration?
Send your current calibration certificate or an instrument list through the form on this page. Labcal prices the same points and ranges as your existing certificate, so you can compare suppliers on equal terms. We respond to all enquiries within one working day.
What does a Labcal UKAS calibration certificate show?
A Labcal UKAS certificate records the measured results at each calibrated point, the error against the reference and the expanded uncertainty (k=2). It carries the UKAS mark and Lab 0625, identifying the work as calibration within Labcal’s accredited scope.
Does Labcal calibrate instruments from any manufacturer?
Yes. Labcal is an independent laboratory and calibrates instruments regardless of brand. If you are unsure whether a specific instrument falls within the UKAS scope, include the make and model in your enquiry and Labcal will confirm.
What happens if my instrument is outside the UKAS accredited range?
Where an instrument or range falls outside the UKAS schedule, Labcal can usually provide a traceable, non-UKAS calibration instead. The quote states clearly which points are UKAS accredited and which are traceable, so there are no surprises when the certificate arrives.
What is the difference between traceable and UKAS-accredited calibration?
Traceable calibration means the chain of measurement leads back to national standards, but says nothing about the laboratory doing the work. UKAS accreditation adds an independent technical assessment of the laboratory itself, covering its equipment, methods, staff competence and quality management system against ISO/IEC 17025:2017.
Request a calibration quote
Tell us what you need calibrating. We respond to all enquiries within one working day with a price and turnaround time.
We respond to all enquiries within one working day. Average turnaround is 7 working days once instruments are received.